Room Air Conditioner Replacement Parts TitanPro TOCF7.5 HVAC Motor Run Oval Capacitor. 7.5 MFD/UF 440/370 Volts

  • Product Name:Air Conditioner Starting capacitor.
  • This operating capacitor is suitable for start-up of single-phase motors with frequencies of 50 Hz and 60 Hz, such as air conditioners, compressors and motors..
  • Package Content: 1 Pcs x 30uF CBB65 Capacitor.
Check Stock

Meter Star ROHS CQC EN60252-1 Universal Air Conditioning Compressor Start-up Capacitor 20-75uf CBB65A-1 450VAC 50/60Hz C S2(P2) SH 40/70/21 Plant Oil (60uf)

  • Meter Star ROHS CQC EN60252-1 Universal Air Conditioning Compressor Start-up Capacitor CBB65A-1 450VAC 50/60Hz C S2(P2) SH 40/70/21 Plant oil ,Capacitor capacity error of 5%.
  • For single-phase motor start-up and operation with a frequency of 50Hz/60Hz AC power supply.
  • 100% oil-immersed capacitor, multi-forced certification, explosion-proof capacitor, metal housing.
  • Connect Pin Size: 4+2 6.3*0.9mm,For more parameters please see the details picture..
  • More models 20uf-75uf, can be contacted by us, 100% quality assurance.
Check Stock

Takaratomy Beyblade Burst B-191 Overdrive SP Starter Set + Bay Random Stickers (Japan Import Shipping from Tokyo)

  • √Parts number: SPP5 Hard Start Capacitor STARTER POW-R-PAK.
  • √Easy to install: Easy 2-wire installation..
  • √This unit can be used on all pcs single phase 120v THRU 288v air conditioning units from 4,000 to120,000 BTU. (1/2 THRU 10 H.P.).
  • √Increases compress TORQUE 300%. Solid state relay and hard start capacitor. STARTER POW-R-PAK..
  • √The replacement part is made from durable high quality material and well-tested by the manufacturer..
Check Stock

SUPCO SPP6 Relay/Capacitor Hard Start Kit with 500% Increase Starting Torque

  • Relay/capacitor hard start kit 500% incr starting torque.
  • Increased compressor starting torque. Designed for use on permanent split capacitor single phase a/C and heat pump systems.
Check Stock

5 HP 3450 RPM R56Y Frame 208-230V Air Compressor Motor - Century # B384

  • Price For: Each Motor Shaft Design: Keyed Hz: 60 Motor Bearings: Ball Motor Shaft Rotation: CCWSE Phase: 1 Ins. Class: B Full Load Amps: 22.0 Motor Mounting Type: Rigid Base Shaft Length: 2-1/4″ Max. Ambient Temp.: 40 Degrees C Capacitor Included: Yes Motor Application: Air Compressor Motor Enclosure Design: Open Dripproof Item: Air Compressor Motor.
  • Nameplate RPM: 3450 HP: 5 Motor Thermal Protection: Manual Motor Design: Capacitor-Start/Run Shaft Dia.: 7/8″ Duty: Continuous Voltage Compatibility: 115/208-230, 208-230, 208-240 Motor Service Factor: 1.15 Frame: 56Y Voltage: 208-230 Overall Length: 14-5/8″ Country of Origin (subject to change): China.
Check Stock

NEW 2 HP SPL Compressor Duty Electric Motor, 3450 RPM, 56 Frame, 5/8\ Shaft Diameter,120/240 VOLT

  • 2 HP SPL COMPRESSOR DUTY ELECTRIC MOTOR, ODP (OPEN DRIP PROOF) FOR DRY INDOOR ENVIRONMENTS.
  • 1 PHASE, 56 FRAME, 3450 RPM, 120V/240VAC, 5/8" SHAFT DIAMETER.
  • CAPACITOR START AND CAPACITOR RUN CONTINUOUS DUTY COMPRESSOR MOTOR.
  • Amperage: (7.5 FLA @ 240V) (15 FLA AT 120V), Voltage: 120V/240V (NOT SUITED FOR 208V INCOMING).
  • CCW (COUNTER CLOCKWISE ROTATION) WHEN VIEWED FROM SHAFT END. MODEL: 56S34D2M EMZ BRAND AND EMZ INDUSTRIES INC.
Check Stock

Grizzly Industrial G0513-17" 2 HP Bandsaw

  • Blade sizes available 1/8-Inch - 1-Inch • Standard blade length: 131 1/2-Inch • Blade speeds: 2 speeds 3500 1600 FPM • Approximate ship.
  • Motor: TEFC capacitor start induction 2 HP single-phase/60 Hz 110V/220V • Amps: 20/10 • RPM: 1725 • Power transfer: Belt d.
Check Stock

Goulds J10S Shallow Well Jet Pump

  • See all sketch images for more details, NEMA standard, 60 Hz, 1 HP, 115/230 V capacitor start, single phase, 3500 RPM.
  • Built-in overload with automatic reset, stainless steel shaft, pressure regulator included..
  • Rotation: Clockwise when viewed from motor end, UL778 listed.
  • Pipe connections: 1. 25" Npt suction and 1" Npt discharge, pressure switch: as4 preset (30-50 PSI)..
Check Stock

Grizzly Industrial H2936-28 x 39 Downdraft Table

  • Motor: TEFC capacitor-start induction, 1/2 HP, single-phase, 110V.
  • Non-marring rubber grommets to support work.
  • Two 110V outlets for plugging in portable sanders.
Check Stock

CBB65A-1 AC 450V Capacitor 30uF Cylindrical Motor Run Round Capacitor for Air Conditioner Motors Refrigerator

  • 【LONG-TERM USE】Metallized polypropylene film non-inductive roller structure improves performance of the product and makes it durable..
  • 【PERFECT PERFORMANCE】Reliable insulation performance, excellent electrical properties and safe explosion-proof devices..
  • 【ADVANTAGE】450V AC run start capacitor with the following advantages,heat resisting, small size, large capacity, low loss and good stability of capacitance..
  • 【STRONG OVERLOAD ABILITY】Current with good impact resistance, strong overload ability..
  • 【SUITABLE FOR】This AC capacitor is suitable for the start-up and operation of single-phase motors with frequency of 50HZ and 60Hz, such as air conditioners, compressors and motors..
Check Stock

CBB60 Run Capacitor with Wire Lead 250V AC 100uF 50/60Hz Run Round Capacitors for Motor Air Compressor, Air Conditioners, Compressors and Motors - Heat Resisting, Low Leakage and Low Impedance

  • ★【Superior Performance】The runn capacitor shell is made of high-quality plastic material and the metallized polypropylene film roll structure of the capacitor improves the performance and durability of the product..
  • ★【Low Energy Consumption】The capacitor with heat resisting, low leakage, low loss and low impedance..
  • ★【Strong Overload Capability】The current has good impact resistance and strong overload capability..
  • ★【Widely Application】This operating capacitor is suitable for start-up of single-phase motors with frequencies of 50 Hz and 60 Hz, such as air conditioners, compressors and motors..
  • ★【High safety】This CBB60 capacitor with reliable insulation performance, excellent electrical properties and safe explosion-proof devices..
Check Stock

Goulds-J7S Single Nose Shallow Well Goulds-Jet Pump 3/4HP

  • See all sketch images for more details, NEMA standard, 60 Hz, 3/4HP, 115/230 V capacitor start, single phase, 3500 RPM.
  • Built-in overload with automatic reset, stainless steel shaft, pressure regulator included..
  • Rotation: Clockwise when viewed from motor end, UL778 listed.
  • Pipe connections: 1. 25" Npt suction and 1" Npt discharge, pressure switch: as4 preset (30-50 PSI)..
Check Stock

Goulds Pump J5S Shallow Well Jet Pump, 115/230 volt, 1/2 hp

  • Pumps are manufacturer tested and may contain water inside from such testing,.
  • See all sketch images for more details, NEMA standard, 60 Hz, 1/2 HP, 115/230 V capacitor start, single phase, 3500 RPM.
  • Built-in overload with automatic reset, stainless steel shaft, pressure regulator included..
  • Rotation: Clockwise when viewed from motor end, UL778 listed.
  • Pipe connections: 1. 25" Npt suction and 1" Npt discharge, pressure switch: as4 preset (30-50 PSI)..
Check Stock