K Type Thermocouple Temperature Thermocouple Sensor Temperature Detector Temperature Gauge with M4 Thread for 3D Printer Temperature Sensor

  • Type K (chromel–alumel) is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.[10] It is inexpensive, and a wide variety of probes are available in its −200 °C to +1350 °C (−330 °F to +2460 °F) range. Type K was specified at a time when metallurgy was less advanced than it is today, and consequently characteristics may vary considerably between samples. One of the constituent metals, nickel, is magnetic.
  • a characteristic of thermocouples made with magnetic.
  • They operate very well in oxidizing atmospheres. If, however, a mostly reducing atmosphere (such as hydrogen with a small amount of oxygen) comes into contact with the wires, the chromium in the chromel alloy oxidizes. This reduces the emf output, and the thermocouple reads low. This phenomenon is known as green rot, due to the color of the affected alloy. Although not always distinctively green, the chromel wire will develop a mottled silvery skin and become magnetic. An easy way to check for t.
  • Hydrogen in the atmosphere is the usual cause of green rot. At high temperatures, it can diffuse through solid metals or an intact metal thermowell. Even a sheath of magnesium oxide insulating the thermocouple will not keep the hydrogen out..
Check Stock

DRELD Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit with 5/8” -18UNF Inlet Outlet Thermocouple Knob Switch, Fits for Gas Grill, Heater, Fire Pit

  • SIZE: 750 mm thermocouple with M8*1 threaded head. Bakelite knob OD 38mm, D shaft 6.1mm..
  • APPLICATION: The kit is suitable for low pressure repair control system for Gas Grill, Heater, Fire Pit, & Fireplace..
  • MATERIAL: The fire pit gas control valve kit is made of brass and plastic for durable use. Not OEM but fits OEM Standards..
  • HOW TO USE: Fix the valve on a plate or board of your grill or fire pit by the head screw and flange. Connect your inlet and outlet hose on inlet and outlet side. Fix the thermocouple nut M8 on the valve end tightly. Connect thermocouple and end thread well. Open gas by correct size knob and push your valve around 5-10s till the thermocouple head is heated enough. Release your hand and it works properly. If the gas valve shut off again when you release hand, then please check..
  • AFTER SALES SERVICE: The Propane Fire Pit Kit Replacement Part completed with a One-year Warranty. Should be there any question, please feel free to contact us..
Check Stock

WADEO Low Pressure LPG Propane Gas Fireplace Fire Pit Flame Failure Safety Control Valve Kit, Low Pressure Propane Fire Pit Replacement Part with 3/8\ Flare Inlet & Outlet

  • Material: The fire pit gas control valve kit are made of high quality brass material with heavy-duty construction for durable use..
  • Application: Suitable for Low Pressure Repair Control System for Grill, Fire Pit, Fireplace & Heater.
  • Size: Thermocouple Length: 600mm/23.62inch.
  • CE&CSA tested Main Control Valve In & Out with 3/8" Male Flare thread (Max BTU rating: 50000, Working Pressure Max 1/2 PSI, 65 mbar).
  • Package Included: Valve, Thermocouple, Plastic Black Bakelite Knob.
Check Stock

Aupoko Universal Thermocouple Patio Heater Parts, 350 mm Outdoor Heater Replacement Parts M8 x 1 End Connection Nuts Thermocouple 0.4 Meters Length M6 x 0.75 Head Thread 4.8 mm/ 0.19'' Flat Terminal

  • APPLICATION: This 350 mm thermcouple is suitable for patio heater..
  • PREMIUM QUALITY: High standard solid copper and brass material, high temperature resistance protection sleeve..
  • EASY INSTALLATION: You only need less than 10s to open the valve and don't need special tools for it..
  • HIGH TEMPERATURE RESISTANCE: The patio heater thermcouple is high temperature resistance with protection sleeve..
  • SIZE: Universal thermocouple with M6x0.75 thread on head, M8 x 1 end connection nuts thermocouple, total extend length 350 mm, with 4.8 mm/ 0.19'' flat terminal..
Check Stock

Thermco ACC310DLSDIG Laboratory Long Stem Digital Thermometer, 12\ Stem Length, -50 to 300°C Range, +/-1.0°C Accuracy

  • High Temperature K-type Thermocouple Thermometer Set with Stainless Steel Probe.
  • K-type thermocouple wire with Standard Accuracy: +/- 2.2 °C or +/- .75%.
  • 5 ft (155 cm) long thermocouple cable with braided stainless steel cover, mini thermocouple plug made from chromel / alumel.
  • Temperature measurement range: -328 to 932 °F (-200 to 500 °C), short term 1472 °F (800 °C).
  • Grounded K-type Thermocouple junction for fast measurements, 1x 9V battery included.
Check Stock

Instrukart Dry Block High Temperature Calibrator AI-DBC 650 for Calibration Labs Pharmaceutical divisions Thermal Plants divisions Along with Calibration Certificate

  • Accuracy: ±0.6°C, Bath Stability: ±0.5°C.
  • Measuring Functions: J Type Thermocouple, K Type Thermocouple, T Type Thermocouple, R Type Thermocouple, S Type Thermocouple, N Type Thermocouple, MA, MV, Volts, Ohms, RTD (Pt 100).
  • Temperature Steps: 50°C, 150°C, 300°C, 450°C, 600°C.
  • Switch Test: Continuity check with OPEN / CLOSE indication.
  • Transmitter Supply: 24V DC ± 10% (Loop Powered).
  • Power Supply: 230V AC ± 5% / 50Hz, 500 W for 350UTC.
  • Supply Scope: Instrument, Power Cable, Carrying Case, Test Lead(2 & 3 Wire), Insertion Tube, Insertion Tool,Spare Fuses: 6A x 2nos User Manual, Calibration Certificate.
Check Stock

3\ Outside Air Kit for Pellet Stoves with 3\ Air Intake Pipe Including Harman Stoves 3\ X 10'

  • QuadraFire Thermocouple 800, 1000, 1100i, 1200, 1200i Pellet Stoves 812-0210.
  • Top Quality Aftermarket Replacement Part.
  • The Thermocouple is the device that monitors the fire after start-up. Once it reaches temp the thermocouple allows the stove to start feeding on it's own in normal operation mode. If your stove goes out after the initial start-up cycle, more than likely the thermocouple needs to be replaced..
  • Designed Specifically for the above mentioned models.
Check Stock

Montague OVEN THERMOCOUPLE 48\ 1036-7

  • K-type thermocouple connector with real chromel alumel contacts.
  • Miniature or mini k-type connector dimensions.
  • Works with all k-type thermocouple wires and extension wires.
  • Set of 10 male mini thermocouple connector plugs.
  • Compatible with thermocouple plugs from other manufacturers.
Check Stock

Emerson H06F 36 Universal Junction Block Thermocouple 36 inch

  • 36 inch junction block thermocouple with energy cut-off.
  • Stainless steel element construction for prolonged thermocouple life.
  • Standard coaxial thermocouple 11/32 inch double lead thread.
  • Universal adapter fittings included with each kit for replacing thermocouple in most types of pilot burners.
  • Works for both LP and natural gas applications.
Check Stock

Cooper Atkins 35132 Aquatuff with Wrap&Stow Duraneed

  • Waterproof Thermocouple Thermometer - Precise digital thermocouple thermometer, delivers a true +/- 0.9 degrees Fahrenheit accuracy and probes can be replaced in the field without the need for recalibration.
  • Heavy Duty Probe Cable - Patented thermocouple thermometer probe cable that neatly wraps and stows around the instrument. Uses any K Type probe.
  • DuraNeedle Probes - Best used for dense meats. Also works well with soft foods and liquids. Probe is calibrated with instrument for Total System Accuracy.
  • Waterproof Digital Thermocouple - Large easy to read digital LCD display, auto shutoff after 10 minutes of non-use. IPX7 waterproof rated.
  • Cooper-Atkins Corporation - Headquartered in Middlefield, CT, Cooper-Atkins has been a leading manufacturer of quality time, temperature, and humidity instruments serving the Foodservice, HVAC and Healthcare markets since 1885.
Check Stock

GBC Document Camera, Discovery 3000 (DCV10004)

  • pyrometer Temperature range: -50°C to 1300°C ( -58°F to 2372°F) and Overload display alert when input exceeds measurement range pyrometer. Thermocouple Temperature range: -50°C to 1000°C ( -58°F to 1832°F).
  • Designed for use with K-type thermocouples and Selection between Celsius and Fahrenheit.
  • Decimal or round number display selectable (decimal range is -58.0F to999.9F and round number range is -58F to 2372F).
  • Includes 2 Thermocouples ( One 3" K type temperature probe (-58 – 752 °F) and one Kiln Heavy duty K type Thermocouple ( -58°F to 1832°F) and Digital Pyrometer, 9V battery and Manual.
  • Thermocouple Measurement range: 32 - 1832 °F (0 - 1000 °C) Thermocouple Type: K Type Cable length : 3 ft Sensing tip length: 6" (150mm) Stainless Steel Sensing tip diameter: 0.19" (5mm) Thread width : 5/16" (M8) Internal Insulation: Fiber Glass External shielding: Metal Shield (Stainless steel braided).
Check Stock

UNI-T UT701 Single Function Temperature Calibrator

  • 1. Up to 0.05% output accuracy 2. 6-digit display 3. Output functions: DC voltage, resistance, thermocouple, and thermal resistance.
  • 4. 10 thermocouple scales 5. 4 thermal resistance scales 6. High precision automatic cold junction compensation for thermocouple outputs.
  • 7. Manual stepping and automatic stepping and ramping 8. Stores and recalls setups.
Check Stock

ennoLogic Volt mA Thermocouple Loop Process Calibrator eC370T - 0-20V and 4-20mA Simulator – Portable Millivolt mA and Temperature Signal Generator and Meter for Transmitters Current Loops PLC

  • VERSATILE AND ACCURATE VOLT MA THERMOCOUPLE CALIBRATOR: Signal generator, simulator and volt / mA meter for calibrating, testing and repairing milliamp loops, thermocouples, PLC, temperature control and HVAC systems. Easily generate precise test signals for current and voltage devices (mA, mV, V, Celsius and Fahrenheit ranges)..
  • NUMERIC KEYPAD for ease and flexibility in setting output signals configuring options. HOTKEY programming for each numeric key (long-press immediately outputs user-configured voltage, current or temperature signal). RAMP AND LADDER OUTPUT FUNCTIONS can be custom configured. BUILT-IN 24V LOOP SUPPLY lets you power and read a device or transmitter without needing another multimeter. This greatly simplifies testing 2-wire current loops..
  • MEASURE VOLTAGE OUTPUT SIGNALS from process devices and sensors with two input ranges of 0-100mV (0.01mV resolution, 0.06% accuracy) and 0-20V (1mV resolution, 0.08% accuracy). MEASURE CURRENT TRANSMITTERS within a range of 0 to 24mA with 0.001mA resolution and 0.08% accuracy. MEASURE THERMOCOUPLE TEMPERATURES within a range of -250°C to +1800°C and resolution of ±0.7°C to ±2°C (range and resolution depends on thermocouple type, supported are type K, J, E, T, N, S, R, and B.).
Check Stock