CZH-LABS DIN Rail Mount 8 Amp Solid State Relay SSR Module in 4~32VDC Out 100~240VAC 8 Channels

  • MOC3043 Phototriac and BTA12-600B triac (the heatsink is electrically insulated)..
  • Input Action Voltage DC 3 to 32V. LED indication for each channel. Anti-reverse protection diode..
  • Output Load Voltage range AC 100 to 240V (50/60Hz). Maximum on-state average current: 8 Amp, maximum on-state current 12 Amp (< 10 seconds). Isolation: Phototriac. Zero cross: Yes..
  • Terminal Block: Wire range: 24 ~ 12 AWG / 2.5mm square. Strip length: 7mm. Screws - M2.5, steel, Cr3+ Zn plated. Pin header and Cage - Brass..
  • DIN rail mount, Taiwan DINKLE fireproof nylon material DIN rail mount carrier (not China low quality carrier), can support width 35mm / 32mm / 15mm rail. FR-4 fiber glass PCB, dual copper layers..
Check Stock

CZH-LABS DIN Rail Mount 12 Amp Solid State Relay SSR Module in 4~32VDC Out 100~240VAC 1 Channel

  • MOC3043 Phototriac and BTA12-600B triac (the heatsink is electrically insulated)..
  • Input Action Voltage DC 3 to 32V. LED indication for each channel. Anti-reverse protection diode..
  • Output Load Voltage range AC 100 to 240V (50/60Hz). Maximum on-state average current: 12 Amp. Isolation: Phototriac. Zero cross: Yes..
  • Dual input terminal block, you can flexibility to configure the input control mode: Individual / Common Positive / Common Negative..
  • DIN rail mount, Taiwan DINKLE fireproof nylon material DIN rail mount carrier (not China low quality carrier), can support width 35mm / 32mm / 15mm....
Check Stock

CZH-Labs DIN Rail Mount 12V Passive 2 SPST-NO 30Amp Power Relay Module.

  • DIN Rail Mount Passive 2 Channel SPST-NO 30 Amp Power Relay Module..
  • High quality DIN rail mount carrier, can support width 35mm /32mm / 15mm rail..
Check Stock

UNO Screw Terminal Block Breakout Module with Aluminum Enclosure for UNO R3.

  • UNO Screw Terminal Block Breakout Module with Aluminum Enclosure. With the adapter module you can easily extend UNO projects to industrial control....
  • Terminal block pitch 3.5mm/0.138", wire size range 26AWG to 16AWG, strip length 5mm, screw M2 steel, pin header and cage copper. Standard IDC40 pitch....
  • Support for Desktop, Panel mount, Wall-mount or DIN rail mount. DIN rail mount supports vertical or horizontal place mounting. Can support width 35mm....
  • Enclosure: High quality aluminum enclosure, thickness 1.5mm/0.06", with attractive and extremely durable powder coat painting and clear laser marking....
  • Packing list: 1x Terminal Block Board(assembled standoffs and screws), 1x Aluminum enclosure(top and bottom covers), 5x M3x4mm Flat head screws(for....
Check Stock

Electric Meter, KWh Meter, Single Phase 4P LED din Rail Electricity Power Consumption Wattmeter Energy Meter, 10-40A

  • ... 【5+1 LED Digital Display】Standard configuration 5+1(99999.1KWh) digital display. Double color LED of kilowatt meter indicates the power status (green) and the energy pulse signal (red)..
  • 【Easy to Contact】The standard configuration pulse output is passive (polar) and the remote pulse output can be selected as passive (non-polar). KWH meter is easy to contact with various AMR systems and conforms to the standards IEC 62053-31 and DIN43864..
  • 【One-way measurement】One-way measurement of single-phase two - wire active energy consumption. This has nothing to do with the direction of the load current. Comply with IEC 62053-21..
  • 【Two Wiring Methods】The din rail energy meter has direct connection operation, two wiring methods. Standard configuration S type wiring, U type wiring can be selected. Extend the terminal cover to protect the use of the security..
Check Stock

Loulensy AC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-300V AC Output 0-5V DC

  • Working Stability: annual change 003c 0.2%.
  • Impulse Voltage:5KV(peak value),1.2/50uS.
  • Load Capacity: 2 times current continuous.
  • Storage Environment:-40 to +115 degress Centigrade,20%-95% without condensation.
  • Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
  • Power Supply(defaulted):24V DC +/-15% (If 15V or 12V needed,please leave a message).
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
  • Working Environment:-25 to 80 degrees Centigrade,20%-90% without condensation.
  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
Check Stock

Loulensy AC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-400V AC Output 0-5V DC

  • Working Stability: annual change 003c 0.2%.
  • Impulse Voltage:5KV(peak value),1.2/50uS.
  • Load Capacity: 2 times current continuous.
  • Storage Environment:-40 to +70 degress Centigrade,20%-95% without condensation.
  • Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
  • Power Supply(defaulted):24V DC +/-15% (If 15V or 12V needed,please leave a message).
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
Check Stock

Loulensy AC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-150V AC Output 4-20mA DC

  • Working Stability: annual change 003c 0.2%.
  • Impulse Voltage:5KV(peak value),1.2/50uS.
  • Load Capacity: 2 times current continuous.
  • Storage Environment:-40 to +70 degress Centigrade,20%-95% without condensation.
  • Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
  • Power Supply(defaulted):24V DC +/-15% (If 15V or 12V needed,please leave a message).
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
Check Stock

Electrodepot 60 Amp 4 Pole Normally Open Contactor 110-120V Coil Motor Load 40A Lighting 63A Bundle with Slotted Steel Zinc Plated DIN Rail 35 mm x 6 in – 1 Piece with 2#10 Screws

  • BUNDLE CONTENT: 4 ITEMS – One (1) 40A Contactor, one (1) compatible Slotted Steel Zinc Plated DIN Rail and two (2) drive stainless steel truss head....
  • APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
  • COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
  • Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp,....
  • OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
  • DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specifications adopted by European....
Check Stock

Loulensy 3-Phase AC Voltage Transducer Sensor Transformer Transmitter 3-Input 0-300V AC with 3-Output 0-5V DC

  • Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Impulse Voltage:5KV(peak value),1.2/50uS.
  • Default Frequency:40-60Hz(contact us,if you specially need different frequency,e.g. 100Hz).
  • Load Capacity: 2 times current continuous.
  • Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
  • Storage Temperature:-40 to 70 degrees Centigrade,20% to 95% without condensation.
  • Working Stability: annual change 003c 0.2%.
  • Working Environment:-10 to 50 degrees Centigrade,20% to 90% without condensation.
  • Isolation Resistance:003e/=20M Ohm(DC513V).
Check Stock

Baomain DDS238-4 (30-100)Single Phase DIN-Rail Kilowatt Hour kwh Meter 220V 100A

  • Rate Voltage:220V 230V 240V Rate Current:30(100A).
  • 220V Single Phase DIN-rail Kilowatt Hour kwh Meter.
  • Insulation Performance:AC voltage 2KV for 1 minute,impulse voltage 6KV.
  • Accuracy Class:Class 1 Starting Current:0.4%lb.
  • 35mm standard DIN rail installation,complying with standard DIN EN5002.
Check Stock

Loulensy 3-Phase AC Voltage Transducer Sensor Transformer Transmitter 3-Input 0-450V AC with 3-Output 4-20mA DC

  • Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Impulse Voltage:5KV(peak value),1.2/50uS.
  • Default Frequency:40-60Hz(contact us,if you specially need different frequency,e.g. 100Hz).
  • Load Capacity: 2 times current continuous.
  • Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
  • Storage Temperature:-40 to 70 degrees Centigrade,20% to 95% without condensation.
  • Working Stability: annual change 003c 0.2%.
  • Working Environment:-10 to 50 degrees Centigrade,20% to 90% without condensation.
  • Isolation Resistance:003e/=20M Ohm(DC520V).
Check Stock

High Speed Comparator High Speed Frequency Meter Front Shaping Comparator for Low-Voltage Applications Conversion Circuit

  • LOW VOLTAGE APPLICATIONS -- The input common mode range is better than the swing input, which is very suitable for low voltage applications..
  • APPLICATION -- Digital module can be used for wide voltage range and periodic signal shaping..
  • FRONT END ADJUSTMENT -- Used as a front end conditioning module in time domain measurements for frequency and phase difference..
  • PARAMETER -- The input voltage is 10 to 1000mV, the input frequency is about 200MHz DC, and the input impedance is 50 ohms..
  • RAIL TO RAIL OUTPUT -- The output level mode is rail to rail output, which can directly drive TTL / CMOS level..
Check Stock