GCAN-207 RS232/485 to CAN Converter,Realize bidirectional Communication Between RS232 or RS485 Bus and CAN Bus

  • Standard serial port level, RS232 model or RS485 model can switch by software.
  • Conversion direction can be set to: CAN?? Serial, CAN?Serial, CAN?Serial.
  • Serial Bus baud rate range from 600bps to 115200bps.
  • CAN-Bus supports CAN2.0A and CAN2.0B frame format, conform to ISO/DIS 11898 standards.
  • CAN-Bus baud rates range from 5Kbps to 1Mbps.
  • CAN-Bus interface with electrical isolation.
  • CAN-Bus isolation converter insulation voltage: DC 1500V.
  • Working temperature range from -40 to 85 °C.
Check Stock

Loulensy AC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-300V AC Output 0-5V DC

  • Working Stability: annual change 003c 0.2%.
  • Impulse Voltage:5KV(peak value),1.2/50uS.
  • Load Capacity: 2 times current continuous.
  • Storage Environment:-40 to +115 degress Centigrade,20%-95% without condensation.
  • Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
  • Power Supply(defaulted):24V DC +/-15% (If 15V or 12V needed,please leave a message).
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
  • Working Environment:-25 to 80 degrees Centigrade,20%-90% without condensation.
  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
Check Stock

Loulensy AC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-400V AC Output 0-5V DC

  • Working Stability: annual change 003c 0.2%.
  • Impulse Voltage:5KV(peak value),1.2/50uS.
  • Load Capacity: 2 times current continuous.
  • Storage Environment:-40 to +70 degress Centigrade,20%-95% without condensation.
  • Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
  • Power Supply(defaulted):24V DC +/-15% (If 15V or 12V needed,please leave a message).
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
Check Stock

Loulensy AC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-150V AC Output 4-20mA DC

  • Working Stability: annual change 003c 0.2%.
  • Impulse Voltage:5KV(peak value),1.2/50uS.
  • Load Capacity: 2 times current continuous.
  • Storage Environment:-40 to +70 degress Centigrade,20%-95% without condensation.
  • Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
  • Power Supply(defaulted):24V DC +/-15% (If 15V or 12V needed,please leave a message).
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
Check Stock

Loulensy 3-Phase AC Voltage Transducer Sensor Transformer Transmitter 3-Input 0-300V AC with 3-Output 0-5V DC

  • Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Impulse Voltage:5KV(peak value),1.2/50uS.
  • Default Frequency:40-60Hz(contact us,if you specially need different frequency,e.g. 100Hz).
  • Load Capacity: 2 times current continuous.
  • Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
  • Storage Temperature:-40 to 70 degrees Centigrade,20% to 95% without condensation.
  • Working Stability: annual change 003c 0.2%.
  • Working Environment:-10 to 50 degrees Centigrade,20% to 90% without condensation.
  • Isolation Resistance:003e/=20M Ohm(DC513V).
Check Stock

Loulensy 3-Phase AC Voltage Transducer Sensor Transformer Transmitter 3-Input 0-450V AC with 3-Output 4-20mA DC

  • Capacity Max:0-500V AC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Impulse Voltage:5KV(peak value),1.2/50uS.
  • Default Frequency:40-60Hz(contact us,if you specially need different frequency,e.g. 100Hz).
  • Load Capacity: 2 times current continuous.
  • Isolation Withstanding Voltage:AC 2.0KV/min*1mA between input/output/power.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting or pannel mounting.
  • Storage Temperature:-40 to 70 degrees Centigrade,20% to 95% without condensation.
  • Working Stability: annual change 003c 0.2%.
  • Working Environment:-10 to 50 degrees Centigrade,20% to 90% without condensation.
  • Isolation Resistance:003e/=20M Ohm(DC520V).
Check Stock

BreeRainz Din Rail Cutter, Double Groove Rail Cutter Tool w/Dual Scale Measuring Ruler, for 1.4 Inch Iron Aluminum Rails

  • 【Double Groove Rail Cutter】- Featuring 2-groove design. Come with long lever handle. This double groove rail cutter can precisely cut both iron & aluminum Din rails at a time with less effort..
  • 【Smooth Rail Incision】- Differ from band saws incision, sharp blade on the professional din rail cutter can ensure the rail incisions neat & smooth. No complex operation. Just press the handle and cut the rails straight.
  • 【Dual Scale Measuring Ruler】- The new version of manual rail cutter has a dual scale ruler included, which allows you to quickly adjust the cutting length and easily cut rails to your desired sizes..
  • 【Wide Cutting Range】- Various sizes of steel & Aluminum DIN rails can be cut. 20" total cutting length. You just need push the slider, set the cut length, insert the rails and get the rails you need right away..
  • 【Practical Rail Cutting Tool】- Simple Structure w/ portable size. Manual din rail cutter provides a perfect solution for electric power, construction and completing other tedious cutting tasks..
Check Stock

DC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-200V DC Output 0-5V DC

  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-1000V DC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Power Supply:11-30V DC(any stable power,e.g. 15V dc).
  • Working Stability: annual change 003c 0.2%.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
Check Stock

DC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-100V DC Output 0-5V DC

  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-1000V DC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Power Supply:11-30V DC(any stable power,e.g. 15V dc).
  • Working Stability: annual change 003c 0.2%.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
Check Stock

UCTRONICS Raspberry Pi DIN Rail Mount, Compatible with Arduino, RPi 4B/3B+/3B/2B/B+, Pi Zero, Raspberry Pi Pico

  • A DIN option to provide a wide range of flexibility in mounting for multiple SBC devices, such as Raspberry Pi 4, 3 B/B+ and all other A, B and Zero Models, Raspberry Pi Pico, Arduino Uno/Mega 2560, BeagleBone series..
  • The mounting bracket is made of 1.2mm carbon steel, attaches to both the SBC and the DIN rail sturdily, multiple optional mounting holes help you mount the different boards and the DIN rail clips in both horizontal and vertical way..
  • Recommended for creating an array of Raspberry servers, home lab and other industrial projects, make it very professional and easy to maintain when needed..
  • Has no hassle to mount in the 19" rack with UCTRONICS DIN rail rack mount, please search for ASIN B09823N6FY to get it..
  • You'll be getting a mounting bracket, 2 DIN rail clips, and standoffs, and screws..
Check Stock

ASI ASI451124 Single Channel Dual Output Analog Signal Isolator Transmitter Splitter 3-Way Isolation DIN Rail Mount Single 4-20 mA Input Dual 4-20 mA Output

  • Analog Signal Isolator with single input with dual output.
  • Zero and span adjustment for precise calibration.
  • 3-Way isolation to eliminate interference.
  • DIN rail mounting and pluggable terminals for quick installation Screw Clamp terminations for easy wiring.
Check Stock

153200 | Optifuse Automotive Circuit Breaker | 58 VDC High Amp | 200A | Type III | Manual Reset | Surface Mount | Bussman Cross: 185200F-011

  • FUNCTIONS: Used to protect 110V 120V 220V 230V AC circuit from overload and short circuit damage, and can also be used for control and isolation..
  • CURVE C: Magnetic trip range 5-10 times rated current..
  • QUALITY: Silver alloy contacts, flame retardant material shell, color indicator..
  • APPLICATION: Can be used in solar ac systems, RV, home circuits, or other 50/60Hz AC systems..
  • INSTALLATION: Screw clamp wires, 35mm DIN rail mount..
Check Stock

DC Voltage Transducer Voltage Sensor Transmitter Transformer Input 0-200V DC Output 0-10V DC

  • Isolation Resistance:20M Ohm(DC500V) or above.
  • Capacity Max:0-1000V DC (Customerized,contact operator if you need other input ranges,e.g.0-75mV or 0-300V).
  • Power Supply:11-30V DC(any stable power,e.g. 15V dc).
  • Working Stability: annual change 003c 0.2%.
  • Feature:Voltage Terminal Insert,standard din rail(35mm)mounting.
  • Working Environment:-10 to 50 degrees Centigrade,20%-90% without condensation.
Check Stock