Protactor 2 Pole 32 AMP Heavy Duty AC Contactor Replaces Virtually All Residential 2 Pole Models 30 Amps or Less
- 32 FLA Amp Rating – 2 Pole – 24 Volt Coil – Replaces Most 2 Pole Contactors Rated at 20 Amps, 25 Amps, or 30 Amps on Air Conditioners and Heat Pumps.
- Enclosed Contacts and Encapsulated 24 Volt Coil.
- Heavy Lug Terminals and Push-Ons for High Voltage Connections.
- Replaces Virtually All 2 Pole Contactors 32 Amps or Less Used by Carrier – Bryant – Payne, Rheem – Ruud – Weatherking, Lennox – Armstrong – Ducane, Trane – American Standard, York – Coleman – Evcon – Luxaire, Heil – Comfortmaker – Tempstar.
Check StockElectrodepot 40 Amp 12 Pole (4 Pole x 3) Normally Open, 110-120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with 8\ DIN Rail and 2 Number 10 Screws
- BUNDLE CONTENT: 6 ITEMS – Three (3) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
- one (1) compatible Slotted Steel Zinc Plated 35mm x 200mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
- CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
- OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificat....
Check StockElectrodepot 40 Amp 8 Pole (4 Pole x 2) Normally Open, 110/120VAC Coil (Silent Operation), Motor Load 40A and Lighting Load 63A Contactor Bundle with DIN Rail, 35 x 150 mm and 2#10 Screws
- BUNDLE CONTENT: 5 ITEMS – Two (2) 40A 4 Pole Normally Open (NO) Contactors with power status indicator.
- one (1) compatible Slotted Steel Zinc Plated 35mm x 150mm DIN Rail and two (2) stainless steel truss head screws (#10, 1/2") for immediate home or industrial installation.
- CONTACTOR APPLICATIONS – Lighting, motor or switching. AC-1 for resistance furnaces, incandescent lamps or electric heaters.
- and AC-3 for air conditioners, compressors or fans. 24/120/220/277 V, with an energy saving, silent and no humming coil.
- COIL VOLTAGE AND LOAD – Contactor IEC 400V. Coil Voltage 110/120VAC, 50/60 Hz.
- Coil load Inrush 52VA, Sealed 10VA. Inductive/Motor Load: 40Amp, Resistive/Incandescent Load: 63Amp. DC Load: 30Amp @ 24VDC. Compatible with 15 Amp, 20 Amp, 30 Amp, 32 Amp, 40 Amp, 50 Amp, 60 Amp and 63 Amp loads. Power Lug Terminal Capacity AWG # 4.
- OTHER CONTACTOR DETAILS – Contactor type NO with 4 poles, power status indicator. IEC AC Rate: AC-1.
- 8 kW. Electric e strength: 4 kV. Operating Temperature -30…+70 °C (-22…+158 °F). Dimensions (approx.): 54 x 64 x 84 mm / 2.1'' x 2.5'' x 3.3'' (Length x Width x Height).
- DIN RAIL – Standard mounting support for any electromechanical component, including contactors, using the DIN specificatio....
Check StockGoodman - 40 Amp 1 Pole 24v Coil Replacement Contactor C140A
- n accordance with U.L. Bulletin No. 508 "Industrial Control Equipment", contactors meet specifications for devices up to 600 VAC..
- Includes Lug, spade terminals, and covers..
Check StockSurge Guard 40100 Basic Automatic Transfer Switch - 50 Amp
- Time delay at power up. Connection type: Screw terminals.
Check StockNR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A)
- 10.0 - 16.0 Amp, IEC, Overload Relay, Type: Thermal Bi-Metallic. Trip Class 10. Selectable Manual or Automatic Reset. For use with XT Series, Frame D Contactors..
Check StockHeavy HVAC Adaptor Cord HVAC Tools HVAC Accessories Compatible with Yellow Jacket 69522 Power Extension Cord for Yellow Jacket Gauges Apply to Vacuum Pumps,Breaker Finder( RT250, ET300 and ET310)
- Heavy Hvac Tool:HVAC adapter cord is a fast and easy way to get power to run a vacuum or a recover machine.We love it instead of running 100+ feet of cord, we can pull power from a disconnect box, to get the job done..
- HVAC-R Service Technician’s Companion: The reliable circuit breaker finder kit is the perfect accessory for your circuit breaker tracker.You can use Compatible with hvac testing tools, ac tools for hvac, hvac power adapter cord, hvac gauges hoses, hvac tool bag, hvac tools clearance, hvac vacuum hose etc..
- Safe and Reliable:UL certified. Large Clip 0~30Amp, 14AWG Adapter Cord for 120V AC Circuit, 28 inch.The green wire is the real ground wire, which is safer to use, the black is the live wire, and the white is the neutral wire..
- Accessory Upgrades:Upgrade gator clips are made of high quality materials, have a good amount of tension, making the connection more stable, easier to use.Non-slip designed with frictional crocodile teeth help you to grip accessories more firmly. Wire core is thickened by 33%, Cross-sectional area increases to 1 m㎡. Less Resistance, Safer Conduction..
- Highly Suggest: As an HVAC extension cord for HVAC-R service technicians, residential HVAC technicians.It is strongly recommended that you learn how to test....
Check StockPackard - DP301202 C230B 2 Pole 30 Amp Contactor, 120 Voltage Coil
- Compatible with: C230B/ TJT30A120V2P/17325/PC230A/H230A/90-244.
- In accordance with U. L. bulletin no. 508 “industrial control equipment”.
- Contactors meet specifications for devices up to 600 VAC.
- Coils have class b insulation. Resistive Amps : 40.
- Includes lug, spade terminals, and covers.
Check Stock20 in. x 20 in. x 1 in. Basic Household Pleated Air Filter (3-Pack)
- This is a Brand New Upgraded 1 Pole 30 Amp Condenser Contactor.
- This contactor is rated for 30 amps, meaning it is an upgrade for old 25 amp contactors.
- The coil is rated for 24 volts- It also has a sealed contact!.
- This contactor will work with 99% of residential units!.
Check StockLennox - 40 Amp 1 Pole 24v Coil Replacement Contactor C140A
- 40 FLA Amp Rating - 1 Pole - 24 Volt Coil. Replaces Most 2 Pole Contactors Rated at 20 Amps, 25 Amps, 30 Amps, 35 Amps, or 40 Amps on Air Conditioners....
- Can be used for virtually all single pole ac contactor replacements Carrier-Bryant-Payne-Goodman-Amana-Janitrol-Rheem Ruud Weatherking-Lennox,....
- Base assembly is made from high performance Bulk (Dough) molding compounds.
Check Stock115/230VAC Pulling Electric Winch with 11.0 fpm and 2000 lb. 1st Layer Load Capacity
- All brass (no corrosion) series wound that is double sealed.
- Sealed waterproof 600 amp contactors and steel contactor cover for added protection.
- Double sealed drum (gearbox/motor) and sealed 3 stage planetary gears as well as aluminum fairleads and integrated wireless remote.
- Fully sealed to Ip68 standard and tie bars reinforced with steel body.
Check StockTrane • 40 Amp 1 Pole 24v Coil Packard Replacement Contactor C140A
- 200K cycles UL testing approval for Dp contactor.
- Replace SIEMENS 45 series dp contactor 1 pole 40FLA 24V coil.
- UL,CUL CSA, SEV S+, CE Approved AC contactor.All our DP contactors series meet the ARI Standard 780/790-1997 and UL508 standard.
- Replacement parts number: 8910DP41V14, 3100-15Q19, C25ANF140T, 45GG10AJA,HCCY1XQ04GG, C140A, DP40241..
Check StockScrewdriver, 14-in-1 Adjustable Screwdriver with Flip Socket, HVAC Nut Drivers and Bits, Impact Rated Klein Tools 32304
- 14 in 1 HVAC Adjustable Length Impact Screwdriver Flip Sock.
Check Stock