RPi 3.3V to 5V 26 I/O Bidirectional Voltage-Level Shifter Module for Raspberry Pi, Logic Level Converter

  • Reliable and suitable for a wide range of uses..
  • High conversion efficiency, simple regulating operation..
  • Modbus TCP Ethernet Remote IO Module (8DI+8DO+8AI+RJ45+RS485).
  • The M160T Ethernet Remote I/O Module is an industrial class, isolated designed, high reliability, high stability and high precision data acquisition module,.
  • It provides multi I/O, supports standard Modbus TCP, can be intergraded into SCADA, OPC server, and other automation systems. It is design for working in the harsh industrial application environment, widely used in a variety of industrial automation, monitoring system, automatically measurement and control system..
Check Stock

Benchtop Digital Resistance Tester High Accuracy DC Resistance Meter Micro Ohm Meter Tester 1u-20M Ohm RS232 Handler Built-in Comparator 3.5'' TFT LCD AT516 for Testing Various Electronic Components

  • AT516 DC Resistance Tester is a benchtop instrument with fully automated real-time detection controlled by a high-performance ARM microprocessor..
  • The instrument has an accuracy of 0.05% and a measurement range of 1μΩ~20MΩ. The resistance value is displayed in 5 bits with 30000 readings and a maximum sampling speed of 7ms. The instrument has built-in temperature compensation interface to compensate for errors due to temperature..
  • The instrument has built-in 14-step comparator output, which can set 10 qualified files, and all the comparator results can be output through the Handler interface..
  • The instrument comes standard with RS-232 interface, using SCPI (Standard Command for Programmable Instrument standard command set) and Modbus protocol (Modbus has become the national standard GB/T19582-2008) applied to automatic sorting system to complete automatic pipeline test. Communicate with computer, PLC or WINCE device to efficiently perform remote control and data acquisition functions..
Check Stock

Web Power Switch Pro Model

  • Rugged, reliable power control over the web. Industrial quality, 15A.
  • Secure web server with SSL, SSH, HTTPS, SNMP, REST API, MODBUS.
  • Simple web UI, or write your own script or program.
  • AutoPing feature to reliably reboot routers or APs.
Check Stock

Xpress RL5 Auto Relay with 40 Amp 5 Pin, 5 Pack

  • Rugged, reliable power control over the web. Industrial quality, 15A.
  • Secure web server with SSL, SSH, HTTPS, SNMP, REST API, MODBUS.
  • Simple web UI, or write your own script or program.
  • AutoPing feature to reliably reboot routers or APs.
Check Stock

Leviton 800-5372-8K 30 Amp Flush Mount Dryer Receptacle

  • Certified to all applicable standards of ANSI C12.1.
  • Equipped with both Isolated Pulse Output and RS-485 Serial Port (Modbus Native) standard for easy interface with most AMR and BAS systems.
  • Utilizes revenue grade 0.3 accuracy class 0.1A secondary solid core current transformers (CTs) that conform to all applicable ANSI requirements or 1-Percent accuracy split-core CTs.
  • Up to three sets of CTs per phase can be paralleled per meter.
Check Stock

Surecom SW-102HF 1.5-70MHz V.S.W.R. & Power Meter

  • Certified to all applicable standards of ANSI C12.1.
  • Equipped with both Isolated Pulse Output and RS-485 Serial Port (Modbus Native) standard for easy interface with most AMR and BAS systems.
  • Utilizes revenue grade 0.3 accuracy class 0.1A secondary solid core current transformers (CTs) that conform to all applicable ANSI requirements or 1-Percent accuracy split-core CTs.
  • Up to three sets of CTs per phase can be paralleled per meter.
Check Stock

Perytech Logic Analyzer PLA-32128-200MS/s, 32 Channel, 128K Memory per Channel

  • Hardware Function: Data Filter, Noise Filter, Width Trig, Trig Delay.
  • Software Function: Bus Decode, Packet List, Bus Data Export, Bus Packet Trig, Move Synchronously, Bus Analog Display.
  • Bus Decode: I2C, SPI, UART, I2S, PS2, 1-Wire, USB 1.1, S/PDIF, SD, CAN Bus, Lin Bus, 3-Wire, Microwire, SSI, Miller, Manchester, SM Bus, Modbus.
Check Stock

DAE V-75 Vertical Water Meter, 3/4” NPT Couplings, Measuring in Gallons

  • Certified to all applicable standards of ANSI C12.1.
  • Equipped with both Isolated Pulse Output and RS-485 Serial Port (Modbus Native) standard for easy interface with most AMR and BAS systems.
  • Utilizes revenue grade 0.3 accuracy class 0.1A secondary solid core current transformers (CTs) that conform to all applicable ANSI requirements or 1-Percent accuracy split-core CTs.
  • Up to three sets of CTs per phase can be paralleled per meter.
Check Stock

Eletechsup 3 in 1 8ch Input/Output Digital Switch TTL LvTTL CMOS RS485 IO Control Module Modbus Rtu Board for PLC Relay (with Terminal, 4)

  • 8 bit DigitalTTL LvTTL CMOS Input/Output.
Check Stock

2.2KW 3HP Spindle Motor and VFD Set Air Cooled Er20 CNC Spindle with Matching Variable Frequency Drive Inverter 220V

  • 2.2kw Air -cooled Motor Spindle and Matching Inverter.
  • 2200kw Air -cooling High Speed High Precision Spindle.
  • RS485 communication port,adopting standard international MODBUS main circuit control 1.5KW 2HP VFD.
Check Stock

O'skool Router Lift Systems for 3-1/2' Diameter Motors, 9-1/4'' x 11-3/4'' Plate

  • Applicable Models : . Aluminum Router Plate Dimensions are 11-3/4" X 9-1/4" X 3/8"thick, 19.1(3/4”) Radius. Designed for routers with 3-1⁄2-in.-dia of body.(Please check the size of our Router Lift to make sure if it matches your router motor and router table .).
  • Suitable for a Variety of Router Tables: Use bar to adjust the gap between router table and router table top opening. Leveling screws can be adjusted the top and bottom flatness of the router plate and router table. The screws of oval mounting holes can be adjusted to suitable positions according to the locations of the router table style holes, then lock them in place..
  • Quick-cChange Router Bit : Use the router lift’s included crank handle to adjust the height of the router bit easily and precisely from above the table..
  • Rotate the hex hole of the micro-adjustment dial to lift or lower the carriage as needed to position the router bit, every full revolution of the adjusting crank moves the carriag and changes the height of the router bit by +- 1/20,” which is the distance change of a thread. So you can make exact bit height changes..
  • After adjusting the router lift to the needed height, lock the carriage to preventthe router motor from shifting while in use.There are precise centerlines....
Check Stock

HXLPAY Radius Jig Router Templates Corner Routing Templates, ABS+CNC high Hardness Processing Glue, Rounded Corners Bit R5 R10 R15 R20 R25 R30 R35 R40 (1 Set of 4 Packs)

  • ...the corner of the template to be copied and place it on the desired corner of the wood. A complete set of professional tools, easy to use, allows you to save time, and is still trying to freely handle corners in your woodworking projects..
  • [Product usage name 1]: corner jig corner radius routing templates corner jig router corner radius jig corner routing templates hxlpay radius jig router templates juice groove jig radius corner jig router radius guide woodworking radius jig router templates radius router templates radius routing template radius template radius template router round corner router templates..
  • [Product usage name 2]: router bit radius router corner jig set router corner jig router corner radius router corner radius jig router corner radius template router corner template router radius guide router radius jig router round corner template router template routing corners routing jig templates corner radius jig router woodpeckers tools..
Check Stock

O'SKOOL Router Lift Systems for 3-1/2" Diameter Motors, 9-1/4'' x 11-3/4'' Plate 5-Piece Insert Ring Kit

  • Applicable Models : . Aluminum Router Plate Dimensions are 11-3/4" X 9-1/4" X 3/8"thick, 19.1(3/4”) Radius. Designed for routers with 3-1⁄2-in.-dia of body.(Please check the size of our Router Lift to make sure if it matches your router motor and router table .).
  • Suitable for a Variety of Router Tables: Use Cam wheels to adjust the gap between router table and router table top opening. Leveling screws can be adjusted the top and bottom flatness of the router plate and router table. The screws of oval mounting holes can be adjusted to suitable positions according to the locations of the router table style holes, then lock them in place..
  • Quick-cChange Router Bit : Use the router lift’s included crank handle to adjust the height of the router bit easily and precisely from above the table..
  • Rotate the hex hole of the micro-adjustment dial to lift or lower the carriage as needed to position the router bit, every full revolution of the adjusting crank moves the carriag and changes the height of the router bit by +- 0.05,” which is the distance change of a thread. So you can make exact bit height changes..
  • After adjusting the router lift to the needed height, lock the carriage to preventthe router motor from shifting while in use.There are precise cent....
Check Stock