Siemens ECSBPK03 Generator Standby Power Mechanical Interlock

  • Ensures the main breaker within a panel is forced to the off position when standby power is on.
  • For use on Siemens or Murray panels that are 150, 200, or 225 amp, ultimate or rock solid type.
  • Standby power breaker must be a QP or MP double pole breaker.
Check Stock

Reliance Controls TF151W Easy/Tran Transfer Switch for Generators, Small, Gray

  • Offers circuit breaker combinations of 60A for generators and 200A for utility.
  • Interlocked breakers keep generator isolated from utility at all times.
  • May be used as main outdoor panel or to feed a sub-panel.
  • Includes provisions for four to eight branch circuits.
  • Eliminates dangerous backfeeds and electrical overloads.
  • Provision for 4/8 branch circuits (4 one inch spaces). Maximum generator input amps-60. Single phase.
Check Stock

EATON/CUTLER HAMMER TYPE CH 150 & 200 AMP PANEL GENERATOR BREAKER INTERLOCK KIT

  • Fits Cutler Hammer Vertical throw main 150 or 200 amp.
  • 2 1/4 inch spacing between main and branch breaker.
  • Kit includes, Interlock, drill bit, labeling and retaining strap for generator breaker.
  • PLEASE Verify panel type by checking second picture.
Check Stock

Siemens ECSBPK02 Generator Standby Power Mechanical Interlock

  • Main breaker is double pole QP breaker 15-125 Amp.
  • Standby power breaker is a QP or MP type.
Check Stock

Siemens ECSBPK01 Generator Standby Power Mechanical Interlock

  • Main breaker is double pole QP breaker 15-125 Amp.
  • Standby power breaker is a QP or MP type.
Check Stock

GE-200A GE General Electric Generator Interlock Kit for 150 or 200 amp Main Breaker Panel

  • Generator Interlock Kit for GE 150 or 200 amp main breaker.
  • Spacing between main and branch breakers is 1 1/4 inches.
  • Kit includes Interlock, drill bit, labeling and retaining strap for generator breaker.
  • PLEASE Verify panel type by checking second picture.
Check Stock

GE-200VL GE General Electric Generator Interlock Kit for Vertical Main 150 or 200 amp Breaker

  • Generator Interlock Kit for GE vertical 150 or 200 amp main breaker.
  • Spacing between main and branch breakers is 2 1/2 to 3 1/2 inches.
  • Kit includes Interlock, drill bit, labeling and retaining strap for generator breaker.
  • PLEASE Verify panel type by checking second picture.
Check Stock

SD-200SA Square D Generator Interlock Kit for Homeline Meter Main 150 or 200 amp Breaker

  • Generator Breaker Interlock for Square D QO or Homeline Indoor or outdoor with main 100 or 125 amp panels.
  • 3/4 spacing between main and branch breakers.
  • Kit includes Interlock, labeling, drill bit and generator breaker retainer strap.
  • PLEASE Verify panel type by checking second picture.
Check Stock

EAT-CH200XA Eaton or Cutler Hammer Generator Interlock Kit Vertical Throw Main 150 or 200 amp Panel Generator Interlock Kit

  • Fits Cutler Hammer Vertical throw main 150 or 200 amp.
  • 2 1/4 inch spacing between main and branch breaker.
  • Kit includes, Interlock, drill bit, labeling and retaining strap for generator breaker.
  • PLEASE Verify panel type by checking second picture.
Check Stock

Siemens E0816ML1125S EQ 125 Amp, 8-Space, 16-Circuit, Indoor Main Lug Surface Mount Load Center

  • Galvanized carbon steel construction for corrosion resistance.
  • NEMA type-1 enclosure designed for use in indoor installations.
Check Stock

Square D - QO124L125PGC QO Load Center with Cover 125-Amp Convertible Main Lugs 1-Phase 24-Space 34-Circuit Ground Bar

  • Engineered for a quick Plug-on Neutral breaker connection on every circuit, fewer connections, faster installation, no pigtails frees up gutter space.
  • Includes an indoor cover, PK15GTA ground bar and is convertible to a main breaker load center with a QOM1 main breaker (sold separately).
  • Accommodates plug-on secondary surge arrestor (sold separately).
  • Overhead/underground feed simply by rotating the device before installing.
  • Rated 120/240 VAC and 65,000 AIR short circuit current rating.
Check Stock

P4260B3200CU 200-Amp 42-Space 60-Circuit 3-Phase Main Breaker Load Center

  • Three phase 200 Amp main breaker load center with 42 spaces/60 circuits.
  • Features Siemens patented insta-wire technology which allows for quick and easy installation because screws are already backed out, ready for wire insertion on ground and neutral bars.
  • All devices are provided with 2 factory installed ground bars.
  • Mounting tabs on the trim hold the load center in place freeing up both hands to drive the trim screws.
Check Stock

Square D - QO11224L125GRB QO 125 Amp 12-Space 24-Circuit Outdoor Main Lug Load Center with Ground Bar,

  • Includes an outdoor cover and PK15GTA ground bar.
  • Accommodates plug-on secondary surge arrestor (sold separately).
  • Overhead/underground feed simply by rotating the device before installing.
  • Convertible to a main breaker load center with the installation of QOM1 main breaker (sold separately).
  • Rated 120/240 VAC and 65,000 AIR short circuit current rating.
Check Stock